• Induline DW-691
    • Induline DW-691

    Article No. 307005

    Induline DW-691

    Opaque water-based industrial intermediate coating and finishing coat for spraying

    Variant
    Colour: white (RAL 9016) | 3070
    Colour: white (RAL 9016) | 3070
    Please choose a colour
    Size / Quantity

    Brochures and Catalogues

    product.brochures.loading

    Product specifications

    Binder special acrylate polymers
    Density (20°C) approx. 1.14 g/cm³ approx. 1.03 g/cm³ (base C)
    Odour characteristic
    Degree of gloss matt / silk matt

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use indoors and outdoors
    • for dimensionally stable elements
    • For professional users only
    • For use on interior and exterior wood
    • Soft and hard woods
    • Dimensionally stable wood building elements: e.g. windows and doors
    • Intermediate and finishing coats
    • Preferably as a single coat

    Properties

    • Water-based
    • High degree of process reliability for industrial use
    • Good hiding power
    • Good flow properties
    • Supports sealing when used with suitable primer and intermediate coatings
    • Good block resistance
    • Good resistance to yellowing and chalking
    • Dirt-resistant
    • Special combination of binding agents creates an extremely hard-wearing surface
    • Good hail resistance
    • Preparation
      • Substrate requirements

        The substrate must be clean, dry, free of dust, grease and loose substances, and prepared in the correct manner.

        Dimensionally stable wood building elements: wood moisture content 11-15%

      • Preparations

        If necessary, impregnate non-resistant woods with a wood preservative* (*Use biocides safely. Always read the label and product information before use).

        Pre-treat using a suitable primer & intermediate coat and carry out intermediate sanding if necessary.

        If necessary, protect parapet joints with Induline V-Joint Protection or Induline AF-920.

    • Application
      • Temperature of the material, air and substrate: from min. +15 °C to max. +30 °C
      • Stir before use
      • Airless/airmix spraying
      • Dynflow (fully automatic coating plant)
      • The values given are based on undiluted material. The best spraying pattern is achieved if the material has a temperature of 15-20 °C.

        Ensure good ventilation.

        Check colour and compatibility with the substrate by applying a trial coat.

        Airless spraying: nozzle size: 0.28-0.33 mm; material pressure: 70-90 bar.

        Air-mix spraying: nozzle size: 0.28-0.33 mm; material pressure: 70-90 bar, atomiser air pressure 1-2 bar.

        Seal opened containers well and use contents as soon as possible.

    • Application instructions
      • Drying time: can be worked over after 4 h
      • Check colour, adhesion and compatibility with the substrate by setting up a trial area.

        Before coating technically modified woods and wood-based materials, apply the coating to a trial surface and conduct a suitability test on the desired area of use.

        Prior to full application, please apply a test coat to a sample area under practical conditions using the desired system, then test or examine the surface properties.

        Do not use in direct sunlight or at temperatures below +15 °C or above +30 °C.

        Ensure good ventilation.

        Recycling is possible via the standard channels. Liaise with Remmers Technical Service if coatings have been mixed.

        To prevent coloured substances contained in the wood from showing through, use a suitable primer and intermediate coating with a sealing effect on white or light-coloured surfaces.

        With water based coating systems, there is always a residual risk that substances contained in the wood will cause discoloration.

        To avoid thicker coats, e.g. in the case of full-tone colours, pretreat with translucent rather than white primer. Then add the coloured topcoat as the intermediate coat.

        The specifications of VFF Code of Practice HO.03 must be observed with regard to the permitted dry layer thicknesses.

        The system finder on our website www.remmers.com contains coating recommendations for specific wood types to be used when treating windows and exterior doors.

      • Drying

        Dust dry: after approx. 1 hour
        Ready for sanding and next coat: after approx. 4 hours
        (practical values at 23 °C and 50% RH and a wet film thickness of 150 - 175 µm)


        When forced drying takes place, ready for sanding and next coat: 20 minutes flash-off time (at approx. 20 °C and 65-75% RH) / 75 minutes drying time (approx. 38 °C, 1 m/s air circulation) / 20 minutes cooling time

      • Thinning

        If necessary with water (max. 5%)

    • Working tools / cleaning
      • Airless/airmix spraying
      • Dynflow (fully automatic coating plant)
      • Airless-/ Airmix spraying equipment, electrostatic equipment, dynflow equipment

      • Clean tools with water or Aqua RK-898 Cleaning Concentrate immediately after use.

        Ensure that any residue from cleaning is disposed of correctly.

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 15 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 15 months.

    • Usage
      • Approx. 150-325 ml / m² per layer applied
      • two spray applications:
        each 150-175 ml/m² (plus spray loss)
        (corresponds to wet film thickness of 150-175 μm, dry film thickness of 55-65 μm)

        one spray application:
        each 300-325 ml/m² (plus spray loss)
        (corresponds to wet film thickness of 300-325 μm, dry film thickness of 110-120 μm)

        Some figures may differ depending on the colour.

    • General information
      • DIN EN 71-3 "Migration of certain elements":

        This product complies with the limits for the migration of heavy metals to children's toys according to DIN EN 71-3 and thus fulfils one of several further requirements for the safety of children's toys according to the EU "Toy Directive" (2009/48/EC).

        Sealing:

        Sealing compounds must be compatible with the coating and may only be applied once the coating has dried thoroughly.

        Only use sealing profiles that are free of plasticisers.

        Where the coating substances used are rich in colour, colour rub-off may occur, e.g. during cleaning. These effects are temporary and sporadic and do not impact the quality of the product in any way. Please see the technical information contained in TI 5.12 "Paint chalking".

        Production of a brushing quality:

        This product can be used with Induline Mix & Go to produce an easy-to-apply lacquer for reconditioning and repair work.

        Care and maintenance:

        Wood is subjected to great climatic and environmental stresses when outdoors. The coat is susceptible to the processes of natural ageing, wear and decomposition. Decomposition takes place at different speeds, depending on the stress (weak, average, strong) placed on the wood building element. Weathering stages may vary according to the part or element affected. To give wood the longest and best possible protection it is advisable to examine surfaces every year. Any damage found should be addressed immediately after cleaning.

        For cleaning and care, we recommend the care set for windows (2745) and doors (2746).

        We recommend that reconditioning coats be applied using Aqua AG-26 All Primer (7147) and Aqua DL-65 Opaque Top PU (7200) or Aqua VL-66/sm Venti-Coat 3in1 (7090)

        Observe current standards and guidelines for coating wood building elements outdoors (Codes of Practice issued by the German Association of Window and Facade Manufacturers (VFF), Code of Practice No. 18 issued by the German Federal Committee for Paint and the Protection of Material Assets (BFS), guidelines issued by the German Lacquer and Printing Ink Association (VdL) and ift guidelines issued by the Institut für Fenstertechnik).

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.