Article No. 2087325

    PBD 1K S

    Sprayable, solvent-free, polymer-modified bituminous thick coating with rubber granule filler, 1-component

    Variant
    020873 | PBD 1K S
    Size / Quantity

    Product specifications

    Base Plastic bitumen emulsion with rubber granules
    Density of ready-to-use mixture Approx. 1.1 kg/l
    Time until thoroughly dry
    (20 °C/70% relative humidity)
    Approx. 3 days*
    Consistency Viscous, thixotropic
    Crack-bridging ≥ 2 mm
    Cross-slit pressure tests Fulfilled
    Dry residue Approx. 70 vol.%

    * Depending on weather conditions and the thickness of the fresh layer, the specified time may be shortened or extended.

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use on floors/walls indoors
    • Waterproofing of new and old buildings with ground contact
    • Water impact classes W1.1-E, W1.2-E, W2.1-E and W3-E as per DIN 18533
    • Retrofit waterproofing of buildings according to WTA Code of Practice 4-6

    Properties

    • Water-based
    • Solvent-free
    • Highly flexible, elastic and crack-bridging
    • High compressive strength
    • Sprayable
    • Resistant to bodies of water aggressive to concrete (DIN 4030 XA3)
    • Preparation
      • Substrate requirements

        Even-surfaced, mineral substrate.

        Clean, dust-free and capable of supporting a load.

        Prepare concrete substrates at wall/base transition areas by means of mechanical material removal.

        Matt damp surfaces are permitted.

        If necessary, provide damp proofing.

      • Preparations

        Remove projecting seams and mortar remains.

        Break off or chamfer corners and edges.

        Smooth out inner corners using a suitable mineral mortar.

        Close indentations > 5 mm using a suitable mineral material.

        Prime absorbent mineral substrates with Kiesol MB. Prime non-absorbent mineral substrates with BIT Primer [basic] (1:10 in water).

        Create a scratch coat using the product as a contact layer and in order to prevent blisters.

    • Application
      • Application temperature: min. 5 °C max. 30 °C
      • Airless/airmix spraying
      • Ready to use, straight from the container.

        Remove any dried material adhering to the edge of the bucket.

        Apply several layers of the material on to the prepared substrate.

        If a reinforcement fabric is required, embed into the first waterproofing layer.

    • Application instructions
      • In the case of liquid-applied waterproofing materials, direct sunlight and/or wind exposure can cause accelerated skin formation and accompanying blistering.

        Do not apply any further sealing layers until the previous layer has hardened sufficiently.

        Protect freshly coated surfaces from rain, direct sunlight, frost and condensation.

        Protect dry sealant from mechanical damage and UV radiation.

        Please contact Remmers Technical Service (phone +49 5432 83900) before applying with machine processing.

    • Working tools / cleaning
      • Airless/airmix spraying
      • Suitable spraying tools

      • Clean tools with water immediately after use, adding bitumen SHM (0881) if necessary.

        Remove dried-on material using V 101 Thinner (0978).

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 12 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.

    • Usage
      • Approx. 1.5 kg / mm thick layer / m²
      • Approx. 1.5 kg/m²/mm dry layer thickness
        For details see application rate table

    • Application examples
      • Water impact classes
        (according to DIN 18533)

        Dry layer
        thickness
        (mm)
        Wet layer thickness
        (mm)
        Application
        quantity (kg/m²)
        Yield 25 kg (m²)
        W1-E
        Soil moisture and non-pressing water

        ≥ 3 approx. 4,5 approx. 4.5 approx. 5.6

        W2.1-E
        moderate exposure to pressing water
        (immersion depth ≤ 3m)


        ≥ 4 approx. 6.0 approx. 6.0 approx. 4.2
        W3-E
        non-pressing water on earth-covered ceiling

        ≥ 4 approx. 6.0 approx. 6.0 approx. 4.2

        *surface waterproofing only (no abP building certificate as per PG-ÜBB)

        Coating thickness allowance according to DIN 18533

    • General information
      • Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.

        The relevant test certificates must be observed when planning and carrying out work.

        Special agreements and certificates of suitability can be downloaded online at www.remmers.com.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.