Field of application

  • Primer for chemically resistant systems
  • Sealer for chemically resistant systems
  • Top seal for blinding layers in chemically resistant systems

Properties

  • High chemical resistance
  • High mechanical resistance
  • Water vapour diffusion capable
  • Preparation
    • Substrate requirements

      Suitable substrates: concrete and cementitious bonded screed only.

      The substrate must be firm, dimensionally stable, capable of bearing loads and free of loose constituents, dust, oil, grease, rubber marks and other substances that could interfere with adhesion.

      The tensile strength of the surface of the substrate must be at least 1.5 N/mm² on average (smallest individual value of at least 1.0 N/mm²), and the compressive strength must be at least 25 N/mm².

      Concretemax. 6 m% moisture

      Cement screedmax. 6 m% moisture

    • Preparations

      Prepare the substrate by suitable means, e.g. steel ball jetting or diamond grinding, so that it meets the requirements specified above.

      Fill broken out or missing areas in the substrate with the Remmers PCC System flush with the surface.

      Depending on the requirements of the system, make suitable anchoring cuts into the substrate.

  • Application
    • Application temperature: min. 10 °C max. 20 °C
    • By brush / By roller
    • Pot life 10 min
    • As a general principle, higher temperatures will reduce and lower temperatures will increase the times stated.

  • Working tools / cleaning
    • By brush / By roller
    • Rubber blade, trowel, epoxy roller, mixer, compulsory mixer if necessary

    • More detailed information can be found in the Remmers Tool Programme.

      Clean tools, equipment and splashed material immediately while fresh with V 101.

      Take suitable protective and waste disposal measures when cleaning.

  • Storage / shelf life
    • Store frost-free
    • Shelf-life 6 months
    • If stored in unopened original containers in a cool, dry place and protected from frost, at least 6 months for component A, at least 12 months for component B and C and at least 18 months for component D.

  • Usage
    • See Application Examples

  • Application examples
    • Priming

      Apply the mixed resin generously to the surface. Distribute with a suitable tool, e.g. rubber blade, and work into the substrate with an epoxy roller so that pores in the surface of the substrate are completely filled.

      It may be necessary to apply several layers.

      approx. 0.4 kg/m²

    • Sealant

      Immediately spread the material with a rubber blade and subsequently roll over in one direction with a suitable epoxy roller.

      approx. 0.4 kg/m²

    • Top sealant

      Immediately spread the material with a rubber blade and subsequently roll over in one direction with a suitable epoxy roller.

      min. 0.6 kg/m² depending on the blinding material

  • General information
    • Unless otherwise specified, all of the values and application rates given above have been determined under laboratory conditions (20 °C) using standard colours. Slight deviations from these values may arise if the product is worked with on site.

      When coating continuous surfaces, only use materials with the same batch number as slight differences in colour, gloss and texture may occur.

      The resulting surface texture is strongly influenced by the conditions on site and the application method. Therefore, surface texture is not covered by product liability.

      PU concretes in general are functional floor coverings with low requirements with regard to appearance and are generally not colour-fast.

      Even if the flooring is correctly installed, differences in colour, marks made during application, streaking and slight formation of pools cannot be excluded.

      Due to the short reaction time, the coating operation must be well planned and prepared.

      Low thickness and low temperature can affect the visual effect of the finished surface.

      Abrasive mechanical loads leave traces of wear.

      Exposure to vehicles with metal or polyamide tyres as well as dynamic concentrated loads can cause faster wearing of the coating.

      In case of repairs on the surface or working up to existing surfaces, there will be a visible transition in appearance and texture.

      The resistance to chemical substances must be assessed with regard to the temperature of the medium (see chemical resistance list).

      Anti-slip floors naturally require more cleaning effort than smooth surfaces. Therefore, the use of cleaning machines with soft brushes is recommended.

      Further notes on working, system construction and maintenance of the listed products can be found in the latest Technical Data Sheets and the Remmers system recommendations.

  • Disposal instructions
    • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.